9801404075 nsbmet@gmail.com

Electrosurgical Unit ZATHA

  • Rs

  • PPS (Patient Protection System)
PPS applied to monopolar with micro pulse technology make the returnpad burn eliminate by 500 times/ sec contact monitoring system between patient and returnpad. If the contact condition is not good enough to safety level, PPS controls the output power automatically.


  • ACW ( Arc-controlled Wavefrom)

New technology ACW has absolute output power at every mode of Coagulation Blend, Bipolar like various power of general ESU. However unlike general ESU which has "off time" on waveform, it has various frequencies for plus continuity. The feature keeps the output power of general ESU strong and make the electric arc be dramatically depleted. Finally it minimizes not only the carbonization but also second bleeding by adhesion of the tissue.


Specifications



ZATHA 

ZATHA-S

Electrical Specification  

Supply voltage 100-230V100-230V
Frequency 50/60Hz50/60Hz
Power impute during max. 900VA1100VA
FuseT10AT10A
Power output Specification 

Maximum cut(555KHz)200W300W
Maximum  Blend (ACW)
150W200W
Maximum Coage (ACW)
150W200
Maximum Bipolar (ACW)
70W100W
Special Function

Safety system PPS(patient protection system)
New TechnologyACW (Arc Controlled Waveform)
Dimensions and Weight 

Width x Depth x Height 330 x 350 x 130330 x 350x 130
Weight 7.5 kg7.5 kg 

Share
  • PPS (Patient Protection System)
PPS applied to monopolar with micro pulse technology make the returnpad burn eliminate by 500 times/ sec contact monitoring system between patient and returnpad. If the contact condition is not good enough to safety level, PPS controls the output power automatically.


  • ACW ( Arc-controlled Wavefrom)

New technology ACW has absolute output power at every mode of Coagulation Blend, Bipolar like various power of general ESU. However unlike general ESU which has "off time" on waveform, it has various frequencies for plus continuity. The feature keeps the output power of general ESU strong and make the electric arc be dramatically depleted. Finally it minimizes not only the carbonization but also second bleeding by adhesion of the tissue.


Specifications



ZATHA 

ZATHA-S

Electrical Specification  

Supply voltage 100-230V100-230V
Frequency 50/60Hz50/60Hz
Power impute during max. 900VA1100VA
FuseT10AT10A
Power output Specification 

Maximum cut(555KHz)200W300W
Maximum  Blend (ACW)
150W200W
Maximum Coage (ACW)
150W200
Maximum Bipolar (ACW)
70W100W
Special Function

Safety system PPS(patient protection system)
New TechnologyACW (Arc Controlled Waveform)
Dimensions and Weight 

Width x Depth x Height 330 x 350 x 130330 x 350x 130
Weight 7.5 kg7.5 kg 

  • 01. Easy 

  • Easy and quick to setup
  • Save time with automatic access to previously used power setting and modes. 
  • Precise Surgical effect with power control dial 

02. Flexibility

  •  In the lower range, the power setting can be adjusted with high precision thanks to nice control (1 watt).

In the upper range, the power can be adjusted with convenience to setup due to wide control (20 watt).

  • Include both monopolar and bipolar outputs
  • Accepts preferred accessories.

Standard 3-pin pencil and 1-pim pencil, most standard footswitching device, standard 2-pin bipolar footswitching device.


03. Safety

  • Increased patient safety by returnpad contact monitoring system

04. Convenience 

  • Front panel connecting with monopolar 3-pin plug, returnpad connector, bipolar plug and footswitch connector