Electrosurgical Unit ZATHA
- PPS (Patient Protection System)
PPS applied to monopolar with micro pulse technology make the returnpad burn eliminate by 500 times/ sec contact monitoring system between patient and returnpad. If the contact condition is not good enough to safety level, PPS controls the output power automatically.
- ACW ( Arc-controlled Wavefrom)
New technology ACW has absolute output power at every mode of Coagulation Blend, Bipolar like various power of general ESU. However unlike general ESU which has "off time" on waveform, it has various frequencies for plus continuity. The feature keeps the output power of general ESU strong and make the electric arc be dramatically depleted. Finally it minimizes not only the carbonization but also second bleeding by adhesion of the tissue.
Specifications
ZATHA | ZATHA-S | |
Electrical Specification | ||
Supply voltage | 100-230V | 100-230V |
Frequency | 50/60Hz | 50/60Hz |
Power impute during max. | 900VA | 1100VA |
Fuse | T10A | T10A |
Power output Specification | ||
Maximum cut(555KHz) | 200W | 300W |
Maximum Blend (ACW) | 150W | 200W |
Maximum Coage (ACW) | 150W | 200 |
Maximum Bipolar (ACW) | 70W | 100W |
Special Function | ||
Safety system | PPS(patient protection system) | |
New Technology | ACW (Arc Controlled Waveform) | |
Dimensions and Weight | ||
Width x Depth x Height | 330 x 350 x 130 | 330 x 350x 130 |
Weight | 7.5 kg | 7.5 kg |
- PPS (Patient Protection System)
PPS applied to monopolar with micro pulse technology make the returnpad burn eliminate by 500 times/ sec contact monitoring system between patient and returnpad. If the contact condition is not good enough to safety level, PPS controls the output power automatically.
- ACW ( Arc-controlled Wavefrom)
New technology ACW has absolute output power at every mode of Coagulation Blend, Bipolar like various power of general ESU. However unlike general ESU which has "off time" on waveform, it has various frequencies for plus continuity. The feature keeps the output power of general ESU strong and make the electric arc be dramatically depleted. Finally it minimizes not only the carbonization but also second bleeding by adhesion of the tissue.
Specifications
ZATHA | ZATHA-S | |
Electrical Specification | ||
Supply voltage | 100-230V | 100-230V |
Frequency | 50/60Hz | 50/60Hz |
Power impute during max. | 900VA | 1100VA |
Fuse | T10A | T10A |
Power output Specification | ||
Maximum cut(555KHz) | 200W | 300W |
Maximum Blend (ACW) | 150W | 200W |
Maximum Coage (ACW) | 150W | 200 |
Maximum Bipolar (ACW) | 70W | 100W |
Special Function | ||
Safety system | PPS(patient protection system) | |
New Technology | ACW (Arc Controlled Waveform) | |
Dimensions and Weight | ||
Width x Depth x Height | 330 x 350 x 130 | 330 x 350x 130 |
Weight | 7.5 kg | 7.5 kg |
- 01. Easy
- Easy and quick to setup
- Save time with automatic access to previously used power setting and modes.
- Precise Surgical effect with power control dial
02. Flexibility
- In the lower range, the power setting can be adjusted with high precision thanks to nice control (1 watt).
In the upper range, the power can be adjusted with convenience to setup due to wide control (20 watt).
- Include both monopolar and bipolar outputs
- Accepts preferred accessories.
Standard 3-pin pencil and 1-pim pencil, most standard footswitching device, standard 2-pin bipolar footswitching device.
03. Safety
- Increased patient safety by returnpad contact monitoring system
04. Convenience
- Front panel connecting with monopolar 3-pin plug, returnpad connector, bipolar plug and footswitch connector