- Home
- About Us
-
Shop
-
Primary Care
- Stethoscope
- Sphygmomanometer
- Blood Pressure Monitor
- Blood Glucose Meter
- Height and Weight
- Pulse Oximeter
- Spirometers
- Examination Table
- X- Ray Film Viewers
- Human Anatomical Models
- DVT pump
- Defibrillator
- General Practice
- Pediatrics
- Emergency medicine
- General Practice
- Electronic Ventilator
- Emergency medicine, Resuscitation
- ICU (Intensive Care Unit)
- Secondary Care
- Accessories
- Ultra sound
- Medical Technical Facilities
- Furniture, Logistics
-
ECG
- Laboratory
- Medical Consumables
- Orthopedic surgery
- Medical Imaging
- Surgery unit
- Wellness
- Gastroenterology
- Cardiology
- Neurology
- Automatic Medical Gas Supply unit
-
Home Use
- EEG
-
Primary Care
- Contact Us
- FAQ's
6 Channel ECG 601
- Home
- 6 Channel ECG 601
6 Channel ECG 601
- Rs
- TOUCH SCREEN
- COLOR & LARGE DISPLAY
- External USB card store 1000 reports
- Keyboard (Name. Age. Weight. Tall)
- AUTO INTERPRITATION
- SPEED UP TO 50mm/S
- BUILT IN RECHARGABLE BATTERY
- AC/DC POWER SUPPLY
- PC Built in USN/RS232interface
- Software upgrade automatically via USB
Technical Specifications
Lead: Standard 12 leads;
Input circuit: protection against defibrillator;
Acquisition Mode: Simultaneous 12 leads acquisition and asynchronous acquisition;
Measurement Range: ±5mVpp;
Time Constant: ≥3.2s;
Frequency Response: 0.05Hz~150Hz (-3dB);
Sensitivity: 2.5mm/mV, 5 mm/mV, 10 mm/mV, 20 mm/mV;
Input Impedance ≥50MΩ;
Input Circuit Current <0.05µA;
Noise Level <15µVp-p;
Patient Current Leakage <10µA (220V-240V);
Filter:
EMG Filter: 25 Hz / 30 Hz / 40Hz
Low Pass Filter: 75 Hz / 100 Hz / 150Hz
DFT Filter: 0.05 Hz/0.15 Hz/0.25 Hz/0.32 Hz/ 0.5 Hz/ 0.67Hz/ ADS
AC Filter: 50 Hz / 60Hz
CMRR: 100dB;
Recording Mode:
Automatic: 3CH×4+1R, 3CH×4, 6CHx2;
Manual: 4CH, 3CH, 2CH, 1CH
Rhythm: Any lead selectable
Recording System: Thermal matrix printing;
Recording Paper: Roll 80mmx20M;
Paper Speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s;
Interface: Network interface, USB Master/Slave, SD card;
Safety Standard: IEC I/CF;
Sample Rate:
Normal: 1000sps/channel
Power Supply:
AC: 100~240V, 50/60Hz, 30VA~100VA
DC: 14.8V/2200mAh, built-in lithium battery
Size: 250mm (L) ×205mm (W) ×50mm (H)
Net Weight: 1.2Kg
Share
- TOUCH SCREEN
- COLOR & LARGE DISPLAY
- External USB card store 1000 reports
- Keyboard (Name. Age. Weight. Tall)
- AUTO INTERPRITATION
- SPEED UP TO 50mm/S
- BUILT IN RECHARGABLE BATTERY
- AC/DC POWER SUPPLY
- PC Built in USN/RS232interface
- Software upgrade automatically via USB
Technical Specifications
Lead: Standard 12 leads;
Input circuit: protection against defibrillator;
Acquisition Mode: Simultaneous 12 leads acquisition and asynchronous acquisition;
Measurement Range: ±5mVpp;
Time Constant: ≥3.2s;
Frequency Response: 0.05Hz~150Hz (-3dB);
Sensitivity: 2.5mm/mV, 5 mm/mV, 10 mm/mV, 20 mm/mV;
Input Impedance ≥50MΩ;
Input Circuit Current <0.05µA;
Noise Level <15µVp-p;
Patient Current Leakage <10µA (220V-240V);
Filter:
EMG Filter: 25 Hz / 30 Hz / 40Hz
Low Pass Filter: 75 Hz / 100 Hz / 150Hz
DFT Filter: 0.05 Hz/0.15 Hz/0.25 Hz/0.32 Hz/ 0.5 Hz/ 0.67Hz/ ADS
AC Filter: 50 Hz / 60Hz
CMRR: 100dB;
Recording Mode:
Automatic: 3CH×4+1R, 3CH×4, 6CHx2;
Manual: 4CH, 3CH, 2CH, 1CH
Rhythm: Any lead selectable
Recording System: Thermal matrix printing;
Recording Paper: Roll 80mmx20M;
Paper Speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s;
Interface: Network interface, USB Master/Slave, SD card;
Safety Standard: IEC I/CF;
Sample Rate:
Normal: 1000sps/channel
Power Supply:
AC: 100~240V, 50/60Hz, 30VA~100VA
DC: 14.8V/2200mAh, built-in lithium battery
Size: 250mm (L) ×205mm (W) ×50mm (H)
Net Weight: 1.2Kg
Add a Review
You Might Also Like
Add Related products to weekly line up
In The Same Category
9 other products in the same category:
- New
- New
- New
- New
- New
- New
- New
- New
- New