9801404075 nsbmet@gmail.com

Digital Three Channel ECG 301A

  • Rs

Precise ECG Auto-interpretation program;

12 lead ECG simultaneous acquisition and display;

 simultaneous 3lead ECG printing with  80mm thermal paper:

Multiple operation mode: automatic, manual, arrhythmia analysis;

Digital filter elimination EMG, AC, Baseline  Drift interference;

Built-in rechargeable Li-ion battery, 2 hours continuous  working;

Real-time ECG waveform;

External USB card store 1000 reports;

Lead-off detection;

Built in USB/RS 232 interface;

 

Technical Parameter 

· Lead: Standard 12 lead;

· Input circuit: protection against defibrillator;

· Acquisition Mode: Simultaneous 12 leads acquisition and asynchronous acquisition;

· Measurement Range: ±5m Vpp;

· Time Constant ≥3.2s;

· Frequency Response: 0.05Hz~150Hz (-3dB)

· Sensitivity: 2.5mm/mV,5mm/mV,10mm/mV,20mm/mV;

· Input impedance ≥50MΩ;

· Input Circuit Current< 0.05µA;

· Noise Level<15µVp-p;

Patient Current Leakage <10µA (220V-240V)

Filter: 

EMG Filter: 25Hz/ 30Hz/40Hz

Low Pass Filter: 75Hz/ 100Hz/150Hz

 DFTFilter:0.05Hz/0.15Hz/0.25Hz/0.32Hz/0.5Hz/0.67Hz/ADS

AC Filter: 50Hz/60Hz

CMRR: 100dB;

Recording Mode:

Automatic: 3CH x 4 + 1R, 3CH x 4, 6CH x 2;

Manual: 4CH, 3CH,2CH,1CH

Rhythm: Any lead selectable 

Recording System: Thermal matrix printing:

Recording Paper: Roll 80mm x 30M

Paper Speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s;

Interface: Network interface, USB Master/ Slave, SD card;

Safety Standard: IECI/CF;

Sample Rate:

Normal: 1000sps/ channel

Power Supply:

AC: 100~240V, 50/60Hz,30VA~100VA

DC: 14.8V/2200mAh, built-in lithium battery 

 

 

Share

Precise ECG Auto-interpretation program;

12 lead ECG simultaneous acquisition and display;

 simultaneous 3lead ECG printing with  80mm thermal paper:

Multiple operation mode: automatic, manual, arrhythmia analysis;

Digital filter elimination EMG, AC, Baseline  Drift interference;

Built-in rechargeable Li-ion battery, 2 hours continuous  working;

Real-time ECG waveform;

External USB card store 1000 reports;

Lead-off detection;

Built in USB/RS 232 interface;

 

Technical Parameter 

· Lead: Standard 12 lead;

· Input circuit: protection against defibrillator;

· Acquisition Mode: Simultaneous 12 leads acquisition and asynchronous acquisition;

· Measurement Range: ±5m Vpp;

· Time Constant ≥3.2s;

· Frequency Response: 0.05Hz~150Hz (-3dB)

· Sensitivity: 2.5mm/mV,5mm/mV,10mm/mV,20mm/mV;

· Input impedance ≥50MΩ;

· Input Circuit Current< 0.05µA;

· Noise Level<15µVp-p;

Patient Current Leakage <10µA (220V-240V)

Filter: 

EMG Filter: 25Hz/ 30Hz/40Hz

Low Pass Filter: 75Hz/ 100Hz/150Hz

 DFTFilter:0.05Hz/0.15Hz/0.25Hz/0.32Hz/0.5Hz/0.67Hz/ADS

AC Filter: 50Hz/60Hz

CMRR: 100dB;

Recording Mode:

Automatic: 3CH x 4 + 1R, 3CH x 4, 6CH x 2;

Manual: 4CH, 3CH,2CH,1CH

Rhythm: Any lead selectable 

Recording System: Thermal matrix printing:

Recording Paper: Roll 80mm x 30M

Paper Speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s;

Interface: Network interface, USB Master/ Slave, SD card;

Safety Standard: IECI/CF;

Sample Rate:

Normal: 1000sps/ channel

Power Supply:

AC: 100~240V, 50/60Hz,30VA~100VA

DC: 14.8V/2200mAh, built-in lithium battery 

 

 

Add a Review

Your rating: