CT single Syringe Injection System
Technical specification | Description |
Electrical requirement | 220VAC/ 110VAC, 50 or 60Hz, 200VA |
Operation Interface | Available in English, French, Spanish, German and Chinses |
Flow Rate | 0.1-10 m/sec. in increments of 0.1 ml/sec |
Syringe Capacity | 100ml for Zenith- C10; 200ml for Zenith-C20 |
Volume | 0.1 ml to syringe capacity in 0.1 ml increments |
Pressure | Preset limit:300 psi default, user settable from 50to 350 psi in 1 psi increments Display: Real- time pressure curve Change threshold: Stop injection if pressure changing suddenly Alarm: Voice alarm and stop injection when over preset limit |
Injection or scan Delay | 0 to 3559 seconds in 1 sec. increments |
Autofill | Settable flow rate from 3- 8ml/sec., volume from 10ml to syringe capability |
Multi- Phase | 1-8 phases per injection |
Pause Phase | 0~ 999 sec. in 1 sec. increments |
Hold Capability | more then 30 minutes |
Storage Capability | 1000 protocols |
Expel air locked | Unable to inject unless expelling air |
Test injection | Settable flow rate from 0.1- 5ml/sec., volume from 0.1ml to 10ml |
Heat maintainer | 35~38°C (optional) |
Hand switch | Hand switch control pause and continue injection (Optional) |
Emergency stop function | Clicking anywhere on the touch screen of the console or pressing any button on the injection arm to stop protocol injection |
Dimension | Injector Arm and Pedestal: L: 22.8* (58.0cm), W: 12.5 (20.1cm), H: 50.2* (127.5cm) Console: L: 4.55* (11.55 cm). W: 12.68* (31.8cm), H: 9.77* (24.81cm ) Main Controller: L:11.9* (30.2cm) W: 7.4* (9.1cm) H: 4.7* (12cm) |
Weight | Injector Arm and pedestal: 16.5 kg Console: 4.1 kg Main Controller: 6.2kg |
User-friendly Operations
- Programming complex protocols easily on 12" wide touch screen of console
- Performing all operations conveniently either on the console or on the injector arm
- Smart buttons of different functions making operation simply
Reliability & Safety
- High precision of flow rate and volume of injection
- Comprehensive real-time monitoring the pressure and system operating states
- Air expelling lock and warning before injections to reduces risk of air embolism
Science & Humanized Design
- The injection arm's height and direction are adjustable
- The pedestal can be moved and locked randomly at expected place.
- The accessary tray frees the user's hands to focus on the operation.
Multi- purpose functionality
- Designed for use in multiple imaging environment, including CT, peripheral vascular surgery, Mammography, HSG, IV Urography and more
Technical specification | Description |
Electrical requirement | 220VAC/ 110VAC, 50 or 60Hz, 200VA |
Operation Interface | Available in English, French, Spanish, German and Chinses |
Flow Rate | 0.1-10 m/sec. in increments of 0.1 ml/sec |
Syringe Capacity | 100ml for Zenith- C10; 200ml for Zenith-C20 |
Volume | 0.1 ml to syringe capacity in 0.1 ml increments |
Pressure | Preset limit:300 psi default, user settable from 50to 350 psi in 1 psi increments Display: Real- time pressure curve Change threshold: Stop injection if pressure changing suddenly Alarm: Voice alarm and stop injection when over preset limit |
Injection or scan Delay | 0 to 3559 seconds in 1 sec. increments |
Autofill | Settable flow rate from 3- 8ml/sec., volume from 10ml to syringe capability |
Multi- Phase | 1-8 phases per injection |
Pause Phase | 0~ 999 sec. in 1 sec. increments |
Hold Capability | more then 30 minutes |
Storage Capability | 1000 protocols |
Expel air locked | Unable to inject unless expelling air |
Test injection | Settable flow rate from 0.1- 5ml/sec., volume from 0.1ml to 10ml |
Heat maintainer | 35~38°C (optional) |
Hand switch | Hand switch control pause and continue injection (Optional) |
Emergency stop function | Clicking anywhere on the touch screen of the console or pressing any button on the injection arm to stop protocol injection |
Dimension | Injector Arm and Pedestal: L: 22.8* (58.0cm), W: 12.5 (20.1cm), H: 50.2* (127.5cm) Console: L: 4.55* (11.55 cm). W: 12.68* (31.8cm), H: 9.77* (24.81cm ) Main Controller: L:11.9* (30.2cm) W: 7.4* (9.1cm) H: 4.7* (12cm) |
Weight | Injector Arm and pedestal: 16.5 kg Console: 4.1 kg Main Controller: 6.2kg |
User-friendly Operations
- Programming complex protocols easily on 12" wide touch screen of console
- Performing all operations conveniently either on the console or on the injector arm
- Smart buttons of different functions making operation simply
Reliability & Safety
- High precision of flow rate and volume of injection
- Comprehensive real-time monitoring the pressure and system operating states
- Air expelling lock and warning before injections to reduces risk of air embolism
Science & Humanized Design
- The injection arm's height and direction are adjustable
- The pedestal can be moved and locked randomly at expected place.
- The accessary tray frees the user's hands to focus on the operation.
Multi- purpose functionality
- Designed for use in multiple imaging environment, including CT, peripheral vascular surgery, Mammography, HSG, IV Urography and more