Zenith- C60 MRI Injection system
| Technical specification | Description |
| Electrical requirement | Arm Controller: Either electric network or battery |
| Electric Network: 220VAC/ 110VAC, 50 or 60Hz, 200VA | |
| Battery: 8 Ah Lithium polymer battery | |
| Console: Input DC 12V, 2A | |
| Operation Interface | Available in English, French, Spanish, German and Chinses |
| Flow Rate | 0.1-10 m/sec. in increments of 0.1 m/sec |
| Syringe Capacity | 65 ml |
| Volume | 0.1 ml to syringe capacity in 0.1 ml increments |
| Pressure | 350 psi (2415kpa) default |
| Injection or scan Delay | 0 to 3559 seconds in 1 sec. increments |
| Autofill | Settable flow rate from 3- 8ml/sec., volume from 10ml to syringe capability |
| Volume from 10 ml to syringe capability | |
| Injection Capabilities | Settable up to 8 phases |
| Pause Phase | 0~ 999 sec. in 1 sec. increments |
| Hold Capability | more than 30 minutes |
| Storage Capability | 1000 protocols |
| Expel air locked | Unable to inject unless expelling air |
| Test injection | Settable flow rate from 0.1- 5ml/sec., volume from 0.1ml to 10ml |
| Heat maintainer | 35~38°C (optional) |
| Hand switch | Hand switch control pause and continue injection (Optional) |
| Emergency stop function | When the system is injecting, click on any point of the touch screen or any button on the injector arm, the system will stop injection |
| Dimension | Injector Arm and Pedestal: L: 22.5* (57.2cm), W: 22.5* (57.2cm), H: 50.2* (127.5cm) Console: L: 4.55* (11.55 cm). W: 12.68* (31.8cm), H: 9.77* (24.81cm ) Main Controller: L: 16.2* (41.2cm) W: 7.4* (9.1cm) H: 10.0* (25.3cm) |
| Weight | Injector Arm and pedestal: 14 kg Console: 4.1 kg Main Controller: 7.2 kg |
Reliability & Safety:
- Completely non- magnetic structure, without electromagnetic interference ensure works reliable and safely in a strong magnetic filed environment
- Comprehensive real- time monitoring the pressure and system operating states
- Remote control of injection to reduces the radiation harmful to the operators
- Air expelling lock and warning before injections to reduces risk of air embolism
| Technical specification | Description |
| Electrical requirement | Arm Controller: Either electric network or battery |
| Electric Network: 220VAC/ 110VAC, 50 or 60Hz, 200VA | |
| Battery: 8 Ah Lithium polymer battery | |
| Console: Input DC 12V, 2A | |
| Operation Interface | Available in English, French, Spanish, German and Chinses |
| Flow Rate | 0.1-10 m/sec. in increments of 0.1 m/sec |
| Syringe Capacity | 65 ml |
| Volume | 0.1 ml to syringe capacity in 0.1 ml increments |
| Pressure | 350 psi (2415kpa) default |
| Injection or scan Delay | 0 to 3559 seconds in 1 sec. increments |
| Autofill | Settable flow rate from 3- 8ml/sec., volume from 10ml to syringe capability |
| Volume from 10 ml to syringe capability | |
| Injection Capabilities | Settable up to 8 phases |
| Pause Phase | 0~ 999 sec. in 1 sec. increments |
| Hold Capability | more than 30 minutes |
| Storage Capability | 1000 protocols |
| Expel air locked | Unable to inject unless expelling air |
| Test injection | Settable flow rate from 0.1- 5ml/sec., volume from 0.1ml to 10ml |
| Heat maintainer | 35~38°C (optional) |
| Hand switch | Hand switch control pause and continue injection (Optional) |
| Emergency stop function | When the system is injecting, click on any point of the touch screen or any button on the injector arm, the system will stop injection |
| Dimension | Injector Arm and Pedestal: L: 22.5* (57.2cm), W: 22.5* (57.2cm), H: 50.2* (127.5cm) Console: L: 4.55* (11.55 cm). W: 12.68* (31.8cm), H: 9.77* (24.81cm ) Main Controller: L: 16.2* (41.2cm) W: 7.4* (9.1cm) H: 10.0* (25.3cm) |
| Weight | Injector Arm and pedestal: 14 kg Console: 4.1 kg Main Controller: 7.2 kg |
Reliability & Safety:
- Completely non- magnetic structure, without electromagnetic interference ensure works reliable and safely in a strong magnetic filed environment
- Comprehensive real- time monitoring the pressure and system operating states
- Remote control of injection to reduces the radiation harmful to the operators
- Air expelling lock and warning before injections to reduces risk of air embolism
Add a Review
You Might Also Like
Add Related products to weekly line up
In The Same Category