- Home
- About Us
-
Shop
-
Primary Care
- Stethoscope
- Sphygmomanometer
- Blood Pressure Monitor
- Blood Glucose Meter
- Height and Weight
- Pulse Oximeter
- Spirometers
- Examination Table
- X- Ray Film Viewers
- Human Anatomical Models
- DVT pump
- Defibrillator
- General Practice
- Pediatrics
- Emergency medicine
- General Practice
- Electronic Ventilator
- Emergency medicine, Resuscitation
- ICU (Intensive Care Unit)
- Secondary Care
- Accessories
- Ultra sound
- Medical Technical Facilities
- Furniture, Logistics
-
ECG
- Laboratory
- Medical Consumables
- Orthopedic surgery
- Medical Imaging
- Surgery unit
- Wellness
- Gastroenterology
- Cardiology
- Neurology
- Automatic Medical Gas Supply unit
-
Home Use
- EEG
-
Primary Care
- Contact Us
- FAQ's
G3L Patient monitor
- Home
- G3L Patient monitor
G3L Patient monitor
- Rs
Feature
· Super ability in against electrosurgical interference. Neither in cutting or in buming, the ECG waveform and HR can be influenced, very short recovering time after defibrillation, especially suitable for use in emergency or operating room.
· Unique thoracic impedance & nasal tube double model respiration test method (when patient can not lie quietly, only tube respiration can detect the right respiration waveform and respiration rate)
· 15" color TFT LCD screen with multi-channel waveform display. lightness And volume are adjustable independently.
· Streamlined outline design with sense of the times: Foldable handle makes carrying easy.
· User- friendly and man- machine dialogue interface including pop-up menus, dialogue boxes, rotary mouse and remote contrable.
· Low- power design with stand by mode, rechargeable high- energy built- in battery.
· Fast and accurate measurement of blood pressure, with venipuncture function.
· using advanced digital technology, accurately measure the SpO2 in low perfusion situation.
· Huge history trend data storage, up to 360 hours.
· Drug calculation and pace-maker function.
· 5 kinds of fixed display format available include OxyCRG diagram, 7-lead ECG waveform simultaneously, big-font mode and etc; 5 kinds of customized display format can be defined and restored by user.
· Audible & visual alarm available and alarm limits are adjustable .
· Suitable for adults, pediatrics and neonates.
· Applications in bedside and delivery monitoring; Be widely used in patient room, emergency room, operation room, PACU, ICU, CCU, ETC.
· WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible.
· Option of printing function of data, waveform, trend tables and trend diagram.
· Option of 2 channel IBP is available.
Technical Parameters
ECG
Input: 3 wires/ 5 wires ECG cable
Lead section: I, II,III, aVR, aVL, x4 and automatic
Sweep speed: 6.25,12.5, 25,50mm/s
Heart rate range: 15-380bpm
Calibration: ±1mv
SpO2
Display type: Waveform, data
SpO2 measurement range: 0-100%
Accuracy: ± 2%
Pulse measurement range: 30-250bpm
Accuracy: ± 1bpm
NIBP
Philosophy: Oscillometric method
Measurement type: adult, pediatric, neonate
Measurement parameter: Systolic, Diastolic, Mean
Measurement method: manual, automatic, continuous measurement
unit: mmHg/kPa selected
Accuracy: ± 2 or 3mmHg
Anesthesia gas analysis (option)
Method: Infrared Absorption
Gas Sorts: CO₂ N₂O, Des, Iso, Enf, Sev, Hal, O₂
Measurement range; Co₂: 0-30% N₂O, O₂: 0-150%
Enf, Iso, Hal, Sev, Des: 0-30%
Data output: Fi and ET values
Agent mixture detection
Power requirement: 100-240V AC, 50/60Hz
Respiration
Thoracic impedance & nasal tube double method selected
Measurement rang: 0-12bpm
Accuracy: ± 1bpm
Resolution: 1bpm
Temperature
Number of channel: 2 channels
Resolution: 0.1 ℃
Display: T1, T2, T
SpO2
Display type: Waveform, data
SpO2 measurement range: 0-100%
Accuracy: ±2%
Pulse measurement range: 30-250bmp
Accuracy: ±1bpm
2-IBP ( invasive blood pressure) (optional)
Measuring range: -6-40k pa (-50-300mmHg)
Channel: 2 channels
Transducer sensitivity: 5MV/V/mmHg
Accuracy: 1mmHg or ±2%
Unit display: kPa or mmHg selectable
Pressure label: ART, CVP, RVP, LAP, RAP, ICU, LVP
Cardiac Output (option)
Measuring Method: thermodilution
Measuring range: CO: 0.1-20.OL/min TB: 23℃-43℃ TI:0℃ -27℃
Resolution: CO: 0.1L/min TB: 0.1℃ TL: ±2℃
Accuracy: CO:±2L/min or ±5% TB:±0.2℃ TI:±0.2℃
Parameter output: Cardiac output hemodynamics calculation
Share
Feature
· Super ability in against electrosurgical interference. Neither in cutting or in buming, the ECG waveform and HR can be influenced, very short recovering time after defibrillation, especially suitable for use in emergency or operating room.
· Unique thoracic impedance & nasal tube double model respiration test method (when patient can not lie quietly, only tube respiration can detect the right respiration waveform and respiration rate)
· 15" color TFT LCD screen with multi-channel waveform display. lightness And volume are adjustable independently.
· Streamlined outline design with sense of the times: Foldable handle makes carrying easy.
· User- friendly and man- machine dialogue interface including pop-up menus, dialogue boxes, rotary mouse and remote contrable.
· Low- power design with stand by mode, rechargeable high- energy built- in battery.
· Fast and accurate measurement of blood pressure, with venipuncture function.
· using advanced digital technology, accurately measure the SpO2 in low perfusion situation.
· Huge history trend data storage, up to 360 hours.
· Drug calculation and pace-maker function.
· 5 kinds of fixed display format available include OxyCRG diagram, 7-lead ECG waveform simultaneously, big-font mode and etc; 5 kinds of customized display format can be defined and restored by user.
· Audible & visual alarm available and alarm limits are adjustable .
· Suitable for adults, pediatrics and neonates.
· Applications in bedside and delivery monitoring; Be widely used in patient room, emergency room, operation room, PACU, ICU, CCU, ETC.
· WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible.
· Option of printing function of data, waveform, trend tables and trend diagram.
· Option of 2 channel IBP is available.
Technical Parameters
ECG
Input: 3 wires/ 5 wires ECG cable
Lead section: I, II,III, aVR, aVL, x4 and automatic
Sweep speed: 6.25,12.5, 25,50mm/s
Heart rate range: 15-380bpm
Calibration: ±1mv
SpO2
Display type: Waveform, data
SpO2 measurement range: 0-100%
Accuracy: ± 2%
Pulse measurement range: 30-250bpm
Accuracy: ± 1bpm
NIBP
Philosophy: Oscillometric method
Measurement type: adult, pediatric, neonate
Measurement parameter: Systolic, Diastolic, Mean
Measurement method: manual, automatic, continuous measurement
unit: mmHg/kPa selected
Accuracy: ± 2 or 3mmHg
Anesthesia gas analysis (option)
Method: Infrared Absorption
Gas Sorts: CO₂ N₂O, Des, Iso, Enf, Sev, Hal, O₂
Measurement range; Co₂: 0-30% N₂O, O₂: 0-150%
Enf, Iso, Hal, Sev, Des: 0-30%
Data output: Fi and ET values
Agent mixture detection
Power requirement: 100-240V AC, 50/60Hz
Respiration
Thoracic impedance & nasal tube double method selected
Measurement rang: 0-12bpm
Accuracy: ± 1bpm
Resolution: 1bpm
Temperature
Number of channel: 2 channels
Resolution: 0.1 ℃
Display: T1, T2, T
SpO2
Display type: Waveform, data
SpO2 measurement range: 0-100%
Accuracy: ±2%
Pulse measurement range: 30-250bmp
Accuracy: ±1bpm
2-IBP ( invasive blood pressure) (optional)
Measuring range: -6-40k pa (-50-300mmHg)
Channel: 2 channels
Transducer sensitivity: 5MV/V/mmHg
Accuracy: 1mmHg or ±2%
Unit display: kPa or mmHg selectable
Pressure label: ART, CVP, RVP, LAP, RAP, ICU, LVP
Cardiac Output (option)
Measuring Method: thermodilution
Measuring range: CO: 0.1-20.OL/min TB: 23℃-43℃ TI:0℃ -27℃
Resolution: CO: 0.1L/min TB: 0.1℃ TL: ±2℃
Accuracy: CO:±2L/min or ±5% TB:±0.2℃ TI:±0.2℃
Parameter output: Cardiac output hemodynamics calculation
Add a Review
You Might Also Like
Add Related products to weekly line up
In The Same Category
41 other products in the same category:
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New
- New