OSEN 9000 Patient Monitor

  • Rs

Offering a one-stop solution for precise patient monitoring, this 12.1 inch Patient Monitor with its multi-channel display, play an important role in hospitals, clinics and emergency units. The unit is capable of performing ST analysis to detect the risk of fetal hypoxia and cardiac arrhythmia analysis to check for abnormalities of the heart. The unit can also check the pulse rate, rate of respiration and warn the doctor in case of apnea. The display is big enough to be read from afar. The unit works on either battery power or electricity.

Share

Offering a one-stop solution for precise patient monitoring, this 12.1 inch Patient Monitor with its multi-channel display, play an important role in hospitals, clinics and emergency units. The unit is capable of performing ST analysis to detect the risk of fetal hypoxia and cardiac arrhythmia analysis to check for abnormalities of the heart. The unit can also check the pulse rate, rate of respiration and warn the doctor in case of apnea. The display is big enough to be read from afar. The unit works on either battery power or electricity.

Features

  •  12.1" color TFT LCD screen, resolution: 800*600
  • 5 kinds of interfaces: Standard/Big font/6-leadn ECG/Trend gragh/OxyCRG
  •  Maximum 8-channel waveforms display, the waveform
  • color can be dened by user (7 colors)
  •  96-hour storage and review of trend graphic gram and
  • table, 400 groups NIBP data, 1800 alarm events Devote to life technology
  •  ST and arrhythmia analysis, pacemaker analysis, drug dose calculation
  • Anti‐debrillation design
  • NIBP over pressure protection
  • Plug‐in rechargeable battery, AC/DC


Technical Specification

ECG

Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)

Lead Selection: I, II, III, avR, avL, avF, V

Waveform: 2 ch

Lead Mode: 3 Leads ( R, L, F or RA, LA, LL)

Lead Selection: I, II, III,

Waveform: 1 ch

Gain:

  • 2.5mm/mV, 5.0mm/mV,
  • 10mm/mV,20mm/mV, auto
  • HR and Alarm Range: Adult: 15 ~ 300 bpm-Neo/Ped: 15 ~ 350 bpm

Accuracy: ±1% or±1bpm, which is greater

Resolution: 1 bpm

Sensitivity: > 200 (uVp-p) Differential

Input Impedance: > 5 MΩ CMRR :

Monitor > 105 dB

  • Operation > 105 dB
  • Diagnosis > 85 dB Electrode

Offset Potential: ±300mV Leakage

Current: < 10 uA

Baseline Recovery: < 3 S After Defi.

ECG Signal Range: ±8 m V ( Vp-p )

Bandwidth:

  • Surgery: 1 ~ 20 Hz
  • Monitor: 0.5 ~ 40 Hz
  • Diagnostic: 0.05 ~ 130 Hz

Calibration Signal: 1 (mVp-p), Accuracy:5% ST

Segment Monitoring Range

Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting:

Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, BRADY, MISSED BEATS, PNP, PNC, Alarm Available, Review Available


RESP

 Method: Impedance Between R-F(RA-LL)

Differential Input Impedance: > 2.5 MΩ

Measuring Impedance Range: 0.3~3 Ω

Base line Impedance Range: 200~4 KΩ

Bandwidth: 0.1~2.5Hz

Resp. Rate:

Measuring and Alarm Range:

  • Adult: 0 ~ 120 Brpm
  • Neo/Ped: 0 ~ 150 Brpm
  • Resolution: 1 Brpm
  • Accuracy: ±2 Brpm
  • Apnea Alarm: 10 ~ 40


NIBP 

Method: Oscillometric Mode:

Manual, Auto, STAT

Measuring Interval in Auto Mode:

1,2,3,4,5,10,15,30,60,90,120,180,240,480 (Min)

Measuring Period in STAT Mode: 5 Min

Pulse Rate Range: 40 ~240 bpm

Alarm Type: SYS, DIA, MEAN

Measuring and Alarms Range:

Adult Mode

SYS: 40 ~240 mmHg

  • ST and arrhythmia analysis, pacemaker analysis, drug does calculation
  • Anti- defibrillation design
  • NIBP over pressure protection
  • Plug-in rechargeable battery. AC/DC avilable
  • Support wire or wireless network


        DIA: 10 ~ 215 mmHg

MEAN: 20 ~ 235 mmHg

Pediatric Mode

  • SYS: 40 ~ 200 mmHg
  • DIA: 10 ~ 150 mmHg
  • MEAN: 20 ~ 165 mmHg

Neonatal Mode

  •        SYS: 40 ~ 135 mmHg
  •           DIA: 10 ~ 100 mmHg
  •           MEAN: 20 ~ 110 mmHg

Resolution: 1mmHg

Accuracy: Maximum Average Error ±5mmHg

Maximum Standard Deviation ±8mmHg

Overpressure Protection Adult

Mode: 297±3 mmHg

Pediatric Mode: 240±3 mmHg

Neonatal Mode: 147±3 mmHg



SpO2

Measuring Range: 0 ~ 100 %

Alarm Range: 0 ~ 100 %

Resolution: 1 %

Accuracy: 70% ~ 100% 2 %

0% ~ 69% unspecied

Actualization Interval: about 1 Sec.

Alarm Delay: 10 Sec.

Pulse Rate:

  • Measuring and Alarm Range: 20~300 bpm
  • Resolution: 1bpm
  • Accuracy: ±3bpm


TEMP

Channel: 2

Measuring and Alarm Range: 0 ~ 50 °C

Resolution: 0.1 °C

Accuracy: ±0.2 °C

Actualization Interval: about 1 Sec.

Average Time Constant:<10 sec 


IBP

Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and Alarm Range:

  • ART: 0 ~ 300 mmHg
  • PA: -6 ~ 120 mmHg
  • CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
  • P1 / P2: -10 ~ 300 mmHg

Press Sensor:

Sensitivity: 5 uV/V/mmHg

Impedance: 300-3000Ω

Resolution: 1 mmHg

Accuracy: ±2% or 1mmHg which is greater

Actualization Interval: about 1 secretary 


Battery: Rechargeable Li-ion battery, 14.8V 2200mAh


Standard: 3/5- Lead ECG, RESP, Spo2, NIBP,PR, TEMP


Optional: Nellcor SpO2, Mainstream/ Sidestream EtCo2, 1/2 channel IBP, Touch Screen, Thermal Recorder, Wall mount, Trolley, Central Station