Amoul T7 Ventilator

  • Rs

  • Elegant and portable design
  • 7" color touch screen with screen lock
  • Real-time display of 4 waveforms and 3 loops
  • Tidal Volume range: 20-2500ml, l:E ratio 1 :59 to 99:1
  • 17 ventilation modes: V-AC, V-SIMV, PRVC, PRVC+, P-AC,P-SIMV, PCV, CPAP, CPAP+, BiPPV, BiPPV+, APRV, APRV+,CPR, RSA, HFNC
  • CPR mode according to AHA guideline
  • 2 trigger way: pressure and flow
  • 02 concentration adjustment from 40% to 100% (21%to100% option)
  • Internal PEEP valve
  • Audible and visual alarm for multi-parameters
  • Optional Mainstream EtC02 with Respironics technology
  • Rechargeable Lion battery with 10 hours standby time, and 5hours working time 


Monitoring Parameters Model T7 
Respiratory frequency 
Obpm~ 120bpm 

1Bpm or 5%
Tidal volume 
20mL~2500mL 

土15mlor土15% 
Minute ventilation 
OL/min~ 120L/m1n 

土0.5L/min or15%
Oxygen concentration
40% ~ 100% , 21%~100% option
 

土10%(v/v)
Airway pressure
-20cmH20~ 100cmH20


土2cmH20 or土10% 
Et-CO2 
OmmHg-150mmHg 

(0-40 mmHg)士2mmHg,
(41-70 mmHg)5%; (71-100 mmHg)8%,
(101-150mmHg)士10% 
Wave display 
Display pressure time waveform 

Display flow time waveform 

Display volumetric time waveform 
Ring diagram Display 
Display pressure volume ring diagram

Display flow volume ring diagram

Display flow pressure ring diagram 


Alarm Parameters Model T7 
Upper limit of minute ventilation 1L/min~120L/min 

High 
Lower limit of minute ventilation 0L/min~119L/min 

High 
Upper limit of airway pressure 15cmH2O~70cmH2O 

High 
Lower limit of airway pressure 0cmH2O~60cm H2O

High 

Respiratory frequency alarm

  • Upper limit 


  • Lower limit 



10bpm~125bpm

Medium 

0mL~2400ml

medium 

Suffocation alarm volume 5~60s

High 
Upper limit of tidal 50mL~3000ml

Medium 
Lower limit of tidal volume 0mL~240ml

Medium 
Upper limit of Et-CO21mmHg~150mmHg

High 
Lower limit of Et-CO20mmHg~149mmHg

High 
Gas Supply Pressure alarm 
Gas supply pressure low Gas supply pressure below 270kpa 

Medium 
Gas Supply pressure high Gas supply pressure higher than 600kpa 

High 
No gas supply pressure Gas supply pressure below 70kpa 

High 
System power supply alarm 
Adapters falling off Adapter fails to be connected 

Medium 
Low battery Minimum work time between alarm and shutdown is 20min 

Medium 
Insufficient battery capacity Battery level is running out 

High 
Respiratory system integrity alarm When respiratory circuit is off, ventilator shall, within3 respiratory cycle, trigger the "Respiratory system Fails to connect Alarm", and give off the voice prompt of "Check Respiratory system & Settings." High level. 
Mute alarm 

≤ 120s


Share
  • Elegant and portable design
  • 7" color touch screen with screen lock
  • Real-time display of 4 waveforms and 3 loops
  • Tidal Volume range: 20-2500ml, l:E ratio 1 :59 to 99:1
  • 17 ventilation modes: V-AC, V-SIMV, PRVC, PRVC+, P-AC,P-SIMV, PCV, CPAP, CPAP+, BiPPV, BiPPV+, APRV, APRV+,CPR, RSA, HFNC
  • CPR mode according to AHA guideline
  • 2 trigger way: pressure and flow
  • 02 concentration adjustment from 40% to 100% (21%to100% option)
  • Internal PEEP valve
  • Audible and visual alarm for multi-parameters
  • Optional Mainstream EtC02 with Respironics technology
  • Rechargeable Lion battery with 10 hours standby time, and 5hours working time 


Monitoring Parameters Model T7 
Respiratory frequency 
Obpm~ 120bpm 

1Bpm or 5%
Tidal volume 
20mL~2500mL 

土15mlor土15% 
Minute ventilation 
OL/min~ 120L/m1n 

土0.5L/min or15%
Oxygen concentration
40% ~ 100% , 21%~100% option
 

土10%(v/v)
Airway pressure
-20cmH20~ 100cmH20


土2cmH20 or土10% 
Et-CO2 
OmmHg-150mmHg 

(0-40 mmHg)士2mmHg,
(41-70 mmHg)5%; (71-100 mmHg)8%,
(101-150mmHg)士10% 
Wave display 
Display pressure time waveform 

Display flow time waveform 

Display volumetric time waveform 
Ring diagram Display 
Display pressure volume ring diagram

Display flow volume ring diagram

Display flow pressure ring diagram 


Alarm Parameters Model T7 
Upper limit of minute ventilation 1L/min~120L/min 

High 
Lower limit of minute ventilation 0L/min~119L/min 

High 
Upper limit of airway pressure 15cmH2O~70cmH2O 

High 
Lower limit of airway pressure 0cmH2O~60cm H2O

High 

Respiratory frequency alarm

  • Upper limit 


  • Lower limit 



10bpm~125bpm

Medium 

0mL~2400ml

medium 

Suffocation alarm volume 5~60s

High 
Upper limit of tidal 50mL~3000ml

Medium 
Lower limit of tidal volume 0mL~240ml

Medium 
Upper limit of Et-CO21mmHg~150mmHg

High 
Lower limit of Et-CO20mmHg~149mmHg

High 
Gas Supply Pressure alarm 
Gas supply pressure low Gas supply pressure below 270kpa 

Medium 
Gas Supply pressure high Gas supply pressure higher than 600kpa 

High 
No gas supply pressure Gas supply pressure below 70kpa 

High 
System power supply alarm 
Adapters falling off Adapter fails to be connected 

Medium 
Low battery Minimum work time between alarm and shutdown is 20min 

Medium 
Insufficient battery capacity Battery level is running out 

High 
Respiratory system integrity alarm When respiratory circuit is off, ventilator shall, within3 respiratory cycle, trigger the "Respiratory system Fails to connect Alarm", and give off the voice prompt of "Check Respiratory system & Settings." High level. 
Mute alarm 

≤ 120s