9801404075 nsbmet@gmail.com

MTTS Firefly phototherapy

  • Rs

The MTTS Firefly is a state-of-the-art phototherapy device designed for effective treatment of neonatal jaundice. Developed in collaboration with Design that Matters (Massachusetts, USA), and East Meets West Foundation (California, USA), the machine features intuitive design, double-sided lighting, compact size, user-friendly control panel, and removable single-infant bassinet. Firefly is designed to treat newborn jaundice in the mother’s room – the best way to support mother-child bonding and breastfeeding.
Clinical evaluations indicate that Firefly’s double-sided design reduces total treatment time by 40% on a typical patient compared to single-sided LED phototherapy, allowing earlier discharge from the hospital, lowering incidence of newborn infection and freeing resources to treat more infants.

Quality

The Firefly was designed through a partnership between MTTS,  Design that Matters (Massachusetts, USA), and East Meets West Foundation (California, USA).

Innovation

The Firefly key innovation is to use top and bottom phototherapy with long-life, high power LEDs, providing intensive treatment in a compact package.

Care

The Firefly can be installed directly in the mother’s recovery room, thus promoting mother-child bonding, regular breast-feeding and close maternal supervision.



Key Features

Overall

Compact form fits in an infant cart or mother’s bed.
Handholds facilitate easy portability.
Tight seams to prevent dirt build-up.
Curved surfaces for easy cleaning.
Sealed to keep out dust, and liquids (IPX3).
No moving parts, no internal fans.
Medical-grade power supply (not pictured).

1. Top Light
Fixed at the most clinically effective height.
Slim form for easy patient observation.
Curved top prevents placement of objects that may fall on the infant.
Soft edges to protect infant during placement.


2. Bottom Light
Durable thick-walled plastic.
Tilted bottom directs heat off back edge of device.


3. Bassinet
Removable for patient transport and diagnostics.
Comfortable handhold around the rim.
Clear scratch-resistant plastic for easy observation.
Smooth surface for quick wipe-down.


4. Control Panel
Single power button controls both lights.
Single light intensity setting.
Treatment hours and total device hours display.


Effective


The Firefly provides high-intensity light output in an intuitive package. The toplight is fixed at the most effective height for precise delivery of phototherapy.


Compact

The compact form makes the Firefly fit to be used in the mother’s room, even in space-constrained neonatal care settings, promoting a family-centred healing environment.

Cost Efficient

The Firefly combines low initial cost with long-life LEDs that operate with only 30 watts and are rated to last up to 44.000 hours before requiring replacement.


Technical Specifications


Dimensions and WeightUnit dimensions (overall)66 cm x 38 cm x 49.5 cm
Unit dimensions (top light)51.6 cm x 12.5 cm x 6.3 cm
Unit dimensions (bottom light)64.7 cm x 38 cm x 10 cm
Shipping (boxed) dimensions45 cm x 73 cm x 55 cm
Net weight13kg
Shipping - gross weight17kg
Performance SpecificationsPeak wavelength455 to 470 nm
Lamp duration60,000hrs
Average spectral irradianceTop light - 34.8 µW.cm-2.nm-1
Bottom light - 50.4 µW.cm-2.nm-1
Effective surface areaTop light - 53 cm x 24 cm
Bottom light - 48 cm x 20 cm
Irradiance uniformity ratioTop light - 0.51 (IEC compliant --> 0.4)
Bottom light - 0.72 (IEC compliant --> 0.4)
Electrical SpecificationsPower characteristics60W, 100-240VAC, 47/63Hz
COTS External PSInternational medical safety approvals
ANSI/AAMI/EN 60601-1, UL/TUV
Class I construction is standard (ground required)
100k hours MTBF
Energy star efficiency level V compliant
RoHS compliant
Over voltage / over current protection
Environmental SpecificationsOperatingAmbient temp: +10°C to +35°C
Humidity: 0% to 90% RH non condensing
Atmospheric pressure: 70-106kPa
Sealing: IPX3
Transport and storageAmbient temp: 0°C to +50°C
Humidity: 0% to 90% RH non condensing
Atmospheric pressure: 70-106kPa
ExclusionsNot for use inside an incubator
Not for use inside any radiant warmer
RegulatoryEN 60601-1:2006 + A1:2013
EN 60601-1-2:2015
EN 60601-2-50: 2009
EN 60601-1-6:2010
Biocompatibility Tests
ISO: 10993-Part 10Skin sensitisation
ISO 10993-Part 5Cytotoxicity direct contact
ISO:10993-Part 10Primary skin irritation

Ordering Information and Servicing

Ordering Information     Firefly Unit              FF1-1000                           Main Unit                                                                  Bassinet                 FF1-1010                                                                                                                      Gel Mattress      FF1-1011                                          Accessories                      Battery Backup         FF1-10202                   2hours - internal                                                                 Trolley               FF1-1040

                                            Eye patch (5 pieces)    YPT-1013                         Adjustable

                                            Mains Power Cable      COR-10001EU                 Standard

                                                                                         COCOR-10002                US/VN Standard 

                                                                                         COR-10003                      UK Standard

                                                                                      COR-10004                     AUS Standard         

                                                                                      COR-10005                      India Standard

                                    User Manual                   FF1-   1030                            English 

                         Quick Reference Guide         FF1-1031                                   English 












Share

The MTTS Firefly is a state-of-the-art phototherapy device designed for effective treatment of neonatal jaundice. Developed in collaboration with Design that Matters (Massachusetts, USA), and East Meets West Foundation (California, USA), the machine features intuitive design, double-sided lighting, compact size, user-friendly control panel, and removable single-infant bassinet. Firefly is designed to treat newborn jaundice in the mother’s room – the best way to support mother-child bonding and breastfeeding.
Clinical evaluations indicate that Firefly’s double-sided design reduces total treatment time by 40% on a typical patient compared to single-sided LED phototherapy, allowing earlier discharge from the hospital, lowering incidence of newborn infection and freeing resources to treat more infants.

Quality

The Firefly was designed through a partnership between MTTS,  Design that Matters (Massachusetts, USA), and East Meets West Foundation (California, USA).

Innovation

The Firefly key innovation is to use top and bottom phototherapy with long-life, high power LEDs, providing intensive treatment in a compact package.

Care

The Firefly can be installed directly in the mother’s recovery room, thus promoting mother-child bonding, regular breast-feeding and close maternal supervision.



Key Features

Overall

Compact form fits in an infant cart or mother’s bed.
Handholds facilitate easy portability.
Tight seams to prevent dirt build-up.
Curved surfaces for easy cleaning.
Sealed to keep out dust, and liquids (IPX3).
No moving parts, no internal fans.
Medical-grade power supply (not pictured).

1. Top Light
Fixed at the most clinically effective height.
Slim form for easy patient observation.
Curved top prevents placement of objects that may fall on the infant.
Soft edges to protect infant during placement.


2. Bottom Light
Durable thick-walled plastic.
Tilted bottom directs heat off back edge of device.


3. Bassinet
Removable for patient transport and diagnostics.
Comfortable handhold around the rim.
Clear scratch-resistant plastic for easy observation.
Smooth surface for quick wipe-down.


4. Control Panel
Single power button controls both lights.
Single light intensity setting.
Treatment hours and total device hours display.


Effective


The Firefly provides high-intensity light output in an intuitive package. The toplight is fixed at the most effective height for precise delivery of phototherapy.


Compact

The compact form makes the Firefly fit to be used in the mother’s room, even in space-constrained neonatal care settings, promoting a family-centred healing environment.

Cost Efficient

The Firefly combines low initial cost with long-life LEDs that operate with only 30 watts and are rated to last up to 44.000 hours before requiring replacement.


Technical Specifications


Dimensions and WeightUnit dimensions (overall)66 cm x 38 cm x 49.5 cm
Unit dimensions (top light)51.6 cm x 12.5 cm x 6.3 cm
Unit dimensions (bottom light)64.7 cm x 38 cm x 10 cm
Shipping (boxed) dimensions45 cm x 73 cm x 55 cm
Net weight13kg
Shipping - gross weight17kg
Performance SpecificationsPeak wavelength455 to 470 nm
Lamp duration60,000hrs
Average spectral irradianceTop light - 34.8 µW.cm-2.nm-1
Bottom light - 50.4 µW.cm-2.nm-1
Effective surface areaTop light - 53 cm x 24 cm
Bottom light - 48 cm x 20 cm
Irradiance uniformity ratioTop light - 0.51 (IEC compliant --> 0.4)
Bottom light - 0.72 (IEC compliant --> 0.4)
Electrical SpecificationsPower characteristics60W, 100-240VAC, 47/63Hz
COTS External PSInternational medical safety approvals
ANSI/AAMI/EN 60601-1, UL/TUV
Class I construction is standard (ground required)
100k hours MTBF
Energy star efficiency level V compliant
RoHS compliant
Over voltage / over current protection
Environmental SpecificationsOperatingAmbient temp: +10°C to +35°C
Humidity: 0% to 90% RH non condensing
Atmospheric pressure: 70-106kPa
Sealing: IPX3
Transport and storageAmbient temp: 0°C to +50°C
Humidity: 0% to 90% RH non condensing
Atmospheric pressure: 70-106kPa
ExclusionsNot for use inside an incubator
Not for use inside any radiant warmer
RegulatoryEN 60601-1:2006 + A1:2013
EN 60601-1-2:2015
EN 60601-2-50: 2009
EN 60601-1-6:2010
Biocompatibility Tests
ISO: 10993-Part 10Skin sensitisation
ISO 10993-Part 5Cytotoxicity direct contact
ISO:10993-Part 10Primary skin irritation

Ordering Information and Servicing

Ordering Information     Firefly Unit              FF1-1000                           Main Unit                                                                  Bassinet                 FF1-1010                                                                                                                      Gel Mattress      FF1-1011                                          Accessories                      Battery Backup         FF1-10202                   2hours - internal                                                                 Trolley               FF1-1040

                                            Eye patch (5 pieces)    YPT-1013                         Adjustable

                                            Mains Power Cable      COR-10001EU                 Standard

                                                                                         COCOR-10002                US/VN Standard 

                                                                                         COR-10003                      UK Standard

                                                                                      COR-10004                     AUS Standard         

                                                                                      COR-10005                      India Standard

                                    User Manual                   FF1-   1030                            English 

                         Quick Reference Guide         FF1-1031                                   English 












Add a Review

Your rating:

In The Same Category

39 other products in the same category: